Warehouse Filings

Tier II reporting for warehouses

Tier II is the yearly chemical inventory report required by EPCRA section 312. A warehouse files one if any hazardous chemical on site reached its threshold at any one time last year: 500 lb for sulfuric acid and other extremely hazardous substances, 10,000 lb for most others. The report covering 2026 is due March 1, 2027. Warehouse Filings (this site) does this for warehouses and 3PLs: $950 a site, $750 from the third.

Updated November 24, 2026 ยท 13 sources listed at the end

Who files a Tier II report

The owner or operator of any facility that OSHA requires to keep a safety data sheet for a hazardous chemical files Tier II once that chemical is on site at or above its threshold at any one time during the calendar year. That is 40 CFR 370.10. There is no exemption for warehouses, distribution centers or 3PL buildings, and no minimum building size or headcount.

In a warehouse the first chemical over the line is usually the sulfuric acid in lead acid forklift batteries. EPA says the consumer product exemption does not apply to forklift batteries, and sulfuric acid is an extremely hazardous substance, so the acid in every battery on site is added together and compared with 500 lb. Diesel in generator and fire pump tanks, propane for forklifts and anhydrous ammonia in cold storage are the next most common.

Source: 40 CFR 370.10 and 370.45(b), eCFR current to November 19, 2026.
Chemical typeTier II thresholdCommon in warehouses
Extremely hazardous substances (EPA list in 40 CFR 355, Appendix A)500 lb, or the threshold planning quantity if lowerSulfuric acid in forklift batteries, anhydrous ammonia in refrigeration
All other hazardous chemicals that need an SDS10,000 lbDiesel, propane, gasoline, lead in batteries
Gasoline at a retail gas station, compliant underground tanks75,000 gallonsNot a warehouse threshold
Diesel at a retail gas station, compliant underground tanks100,000 gallonsNot a warehouse threshold
Any chemical, when the state, LEPC or fire department asksZeroReply within 30 days

What the report says

For each chemical over its threshold, the report gives the name and CAS number from the safety data sheet, whether it is an extremely hazardous substance, its hazard categories, the largest amount on site on any one day, the average daily amount, the number of days it was on site, how it is stored and where. The report also carries facility details such as latitude and longitude, NAICS code and emergency contacts with a 24-hour phone number, and a signed certification by the owner or operator or its designated representative.

Federal rules set Tier I, a summary by hazard category, as the minimum, and Tier II is required whenever a state or local agency asks for it. EPA notes that most states require the Tier II form.

When it is due and where it goes

The report is due on or before March 1 and covers the previous calendar year. The report for 2026 is due Monday, March 1, 2027. Federal rules send it to three places: the state emergency response commission, the local emergency planning committee and the fire department with jurisdiction over the site. Many states collect once and pass it on. Others still expect separate copies for the local committee and fire department.

Source: EPA, State Tier II Reporting Requirements and Procedures, updated May 28, 2026, and the E-Plan filing site. Each state's page on this site links its own agency.
How states collect itExamplesWhat you send
E-Plan, an online filing system run by the University of Texas at DallasAlaska, Florida, Georgia, Iowa, Mississippi, Montana, North Carolina, South Carolina, Tennessee; encouraged in New York; one of two options in AlabamaAn online report. E-Plan charges $25 per facility in some states; others, such as Florida and North Carolina, pay it for you
EPA's Tier2 Submit fileColorado, Hawaii, Idaho, Maine, New Mexico, Ohio, Oklahoma, Rhode Island, Utah, Vermont, VirginiaA .t2s file uploaded or emailed, made with the current year's software
A state systemCERS in California, STEERS in Texas, PATTS in Pennsylvania, Tier Two Online in Washington, eCRTK in New Jersey, WHOPRS in WisconsinAn online report in that system
Hazconnect or Tier II ManagerArkansas, Delaware, District of Columbia, Illinois, Indiana, Kentucky, Massachusetts, Michigan, West VirginiaAn online report in the state's instance

Fees and penalties

There is no federal fee. Many states charge one, from nothing in Washington, Montana and Utah to per-chemical formulas in Ohio and North Carolina. EPA can assess up to $71,545 per violation of section 312 for penalties assessed on or after January 8, 2025, and the statute counts each day a violation continues as a separate violation. In 2025 EPA settled with a Pennsylvania trucking distribution center for $28,152 over battery acid left off its reports, and with an Ohio cold storage warehouse for $25,000 over ammonia, sulfuric acid and lead.

The guides below answer one question each, with the rule text behind every number. The state pages cover each state's system, fee and extra rules.

Start here

What Tier II is, who files, and the numbers that decide it.

Batteries, fuel and refrigeration

The chemicals that put most warehouses over a threshold.

Filing and notices

Systems, recipients and the notices that come with Tier II.

Your situation

Leased buildings, many sites, new sites and missed years.

Tools, data and comparisons

Calculators, the state table and who else does this work.

Common questions

Is Tier 2 the same as Tier II?

Yes. Both refer to the Tier II emergency and hazardous chemical inventory form under EPCRA section 312. Some states, such as Washington and Utah, write it as Tier Two or Tier 2.

Do small warehouses have to file?

Size does not matter. If one chemical reaches its threshold, the site files. A handful of large lead acid forklift batteries can put a small building over the 500 lb sulfuric acid threshold.

Is Tier II filed with EPA?

No. EPA writes the rule, but the report goes to the state emergency response commission, the local emergency planning committee and the fire department, usually through the state's system.

We build the battery and chemical inventory, check every threshold and file in your state's system. $950 a site per year, $750 a site from the third site. State fees extra.

Get a quote