Warehouse Filings

What is the difference between Tier II and TRI reporting?

Tier II, under EPCRA section 312, is an inventory of hazardous chemicals stored on site, due March 1 to state and local responders. TRI, section 313, reports releases and waste of listed toxic chemicals, due July 1 to EPA and the state, and only applies to facilities with 10 or more full-time employees in listed industries.

Reviewed November 2026 ยท 11 sources listed at the end

Two reports under the same law

Both come from EPCRA, the 1986 law also known as SARA Title III. They answer different questions. Tier II, section 312, tells local responders what hazardous chemicals are stored at a site and where. The Toxics Release Inventory, section 313, tells EPA and the public how much of a listed toxic chemical a facility released or sent off as waste in a year.

From 40 CFR 370.10, 370.40 to 370.45, 372.22, 372.23, 372.25 and 372.30, as published on eCFR, current to November 19, 2026.
Tier II (section 312)TRI (section 313)
What it reportsHazardous chemicals on hand: maximum and average amounts, storage and locationReleases and waste management of listed toxic chemicals
Who must fileAny facility OSHA requires to keep an SDS for a chemical at or above thresholdFacilities with 10 or more full-time employees in industries listed in 40 CFR 372.23 that exceed a threshold
Threshold500 lb for extremely hazardous substances (or the planning quantity if lower), 10,000 lb for others, at any one time25,000 lb a year manufactured or processed, or 10,000 lb a year otherwise used
FormTier II form, in the state's systemEPA Form R or Form A
DueMarch 1 for the prior calendar yearJuly 1 for the prior calendar year
Goes toSERC, LEPC and fire departmentEPA and the state
Regulation40 CFR part 37040 CFR part 372

Does a warehouse file TRI?

Usually not, because TRI is limited by industry. 40 CFR 372.22 covers a facility only if it has 10 or more full-time employees, is in an industry code listed in 40 CFR 372.23, and crosses a chemical threshold. The list covers manufacturing, certain mining and utilities, hazardous waste facilities, and a few wholesale codes. Two of those wholesale codes are close to warehousing: NAICS 424690, Other Chemical and Allied Products Merchant Wholesalers, and NAICS 424710, Petroleum Bulk Stations and Terminals. General warehousing and storage codes do not appear in the list as published on eCFR.

A 3PL that runs a chemical distribution operation, or a warehouse attached to a manufacturing plant, should check its primary industry code against 372.23. A general merchandise distribution center almost always files Tier II and not TRI.

The thresholds work differently

Tier II looks at a snapshot: the largest amount present on any one day. TRI looks at a year's throughput: how much was manufactured, processed or otherwise used. A building can hold 7,000 lb of battery acid all year and owe a Tier II report, without ever processing or using a listed chemical in the TRI sense. Both rules ignore small concentrations in mixtures: Tier II and TRI both skip chemicals at 1% or less of a mixture, or 0.1% for carcinogens.

Where they connect

The Tier II form asks for any TRI facility ID the site has been assigned, or N/A (40 CFR 370.42(j)). Maryland caps its combined Community Right-to-Know fees, including Tier II and TRI fees, at $1,000 per owner or operator a year. EPA's lithium-ion battery guidance also notes that batteries exempt from Tier II can still matter for TRI if they contain listed toxic chemicals.

Common questions

Can one chemical be on both reports?

Yes, if the facility is covered by both rules. The thresholds and the data asked for are different, so the numbers will not match.

Is TRI filed in the state Tier II system?

No. TRI goes to EPA and the state under 40 CFR 372.30. Tier II goes to the SERC, LEPC and fire department through the state's chosen system.

Do warehouses file TRI?

Usually not. 40 CFR 372.22 covers a facility only if it has 10 or more full-time employees, is in an industry code listed in 40 CFR 372.23 and crosses a chemical threshold. General warehousing and storage codes do not appear in that list as published on eCFR.

We build the battery and chemical inventory, check every threshold and file in your state's system. $950 a site per year, $750 a site from the third site. State fees extra.

Get a quote