Warehouse Filings
Loading docks of a large distribution warehouse at dusk after rain, trailers backed in at lit dock doors

Tier II and WAIRE filing for warehouses, distribution centers and 3PLs

Tier II and WAIRE reports for warehouses, filed for you

Warehouse Filings counts the acid in your forklift batteries and files your Tier II report in each state's system: $950 a site, $750 from the third. Annual WAIRE Reports for South Coast warehouses: $2,500 a year.

Tier II from $750 a site. WAIRE $2,500 per warehouse per report year. State and AQMD fees are extra.

Tier II due
March 1
Annual WAIRE Report due
January 31
Tier II coverage
50 states and DC
Filed only after
Your approval

What we file

Two reports that warehouse operators owe and often miss. We do the counting, the paperwork and the filing. You approve before anything goes in.

A forklift battery charging room with lead acid batteries on stands connected to wall chargers

DueMarch 1

Tier II chemical inventory

EPCRA section 312 · all 50 states and DC

The yearly report for any site that held a hazardous chemical at or above its threshold during the prior calendar year. In a warehouse it usually starts with the sulfuric acid in forklift batteries, then diesel, propane, or ammonia in cold storage.

Who files
The owner or operator of the site
Due
March 1, covering the prior calendar year
Goes to
The state emergency response commission, the local emergency planning committee and the fire department
Our fee
$950 per site per year, $750 per site from the third site
A battery-electric yard truck moving a trailer across a warehouse truck yard in Southern California

DueJanuary 31

Annual WAIRE Report

South Coast AQMD Rule 2305

The yearly report for warehouse operators in buildings of 100,000 sq ft or more in the South Coast AQMD, which covers large parts of Los Angeles, Orange, Riverside and San Bernardino counties. It shows the points your truck traffic created and how you earned them.

Who files
Operators using 50,000 sq ft or more of the building for warehousing
Due
January 31, covering the prior calendar year
Goes to
South Coast AQMD, through its WAIRE POP portal
Our fee
$2,500 per warehouse per report year, missed years at the same price

What you get back

Every site and every report year ends with the same set of files: the working papers behind each number, a draft for your sign-off, and the agency's confirmation once it is filed.

Forklift battery inventory, 2026Example Logistics Co. · Building 2
Sample
UnitsEquipmentCountWeight eachAcid at 30%
FL-01 to 04Reach truck42,000 lb2,400 lb
FL-05 to 08Order picker41,850 lb2,220 lb
FL-09 to 10Counterbalance22,400 lb1,440 lb
SP-01 to 02Spares, charging room22,000 lb1,200 lb
Total on site1224,200 lb7,260 lb
Tier II threshold 500 lb · 14.5 times overReportable
Tier II threshold review, 2026Example Logistics Co. · Building 2 · E-Plan
Sample
ChemicalMax on one dayThresholdResult
Sulfuric acid, in batteries7,260 lb500 lbReport
Diesel, generator tank11,900 lb10,000 lbReport
Propane, forklift cylinders1,980 lb10,000 lbBelow
Draft sent Feb 9, 2027 for your sign-offReady to file
WAIRE points ledger, 2026Example Logistics Co. · DC 4 · 210,000 sq ft
Sample
Class 8 trips, 15,600 × 2.539,000
Class 2b to 7 trips5,200
Weighted annual truck trips44,200
Points owed, × 0.0025 × 1.0110.5
Zero-emission yard truck use, 312 h90.8
Onsite solar, 1,980,000 kWh12.0
Mitigation fee points, $8,181.25 to AQMD7.7
Due Jan 31, 2027Awaiting your approval

Sample working papers for a fictional 3PL. Acid at 30% of battery weight, the share EPA used in its 2025 Allen Distribution order. WAIRE math from Rule 2305 Tables 2 and 3. Run your own battery count

Each Tier II site

  1. Threshold reviewEach chemical on site, its largest amount on any one day, its threshold under 40 CFR 370.10 or the state's lower one, and a report or below resultDuring scoping, before any fee for that site
  2. Battery and chemical inventoryEvery battery by unit, weight and acid share, spares included; tanks and cylinders by capacity; the document behind each figureWith the draft
  3. Draft Tier II reportThe state's form or system entry, with the EPA range codes for maximum and average daily amounts, days on site, storage types and locationsFor sign-off before filing
  4. Filing confirmationThe agency's receipt or confirmation number and the filed copyOn filing
  5. Copy logProof of the copies sent to the local emergency planning committee and fire department where the state requires themOn filing
  6. Working fileThe spreadsheet behind every number, kept so next year's report starts from itOn filing

Each WAIRE report year

  1. Truck trip countClass 2b to 7 and Class 8 trips for the compliance year, from gate, yard or carrier records, with the record source namedRule 2305 (d)(1)(B), (e)(3)(A)
  2. Points calculationWeighted annual truck trips, the annual variable and the points owedRule 2305 (d)(1)(A), Table 2
  3. Points ledgerEach Table 3 action with its reporting metric and points, plus banked, transferred or mitigation-fee pointsRule 2305 (d)(3), (e)(3)(B) and (C)
  4. Evidence fileProof for every action claimed, collected at the time of the action, organized to be kept seven yearsRule 2305 (e)(4)
  5. Draft report for approvalThe Annual WAIRE Report as it will be entered in WAIRE POP, for your authorized official to reviewRule 2305 (e)(5)
  6. Filed report and fee recordWAIRE POP confirmation and the AQMD filing fee paid by youRule 316, amended May 1, 2026

Batteries are where most warehouse reports start

EPA counts the sulfuric acid in lead acid forklift batteries toward Tier II, and the threshold for sulfuric acid is 500 lb across every battery on site. In 2025 EPA settled with a Pennsylvania trucking distribution center that had 56 batteries holding about 33,599 lb of acid and had reported only the lead. The penalty was $28,152.

Check your batteries

Sulfuric acid threshold, all batteries on site combined
500 lb
Batteries at the Pennsylvania distribution center
56
Acid in those batteries, about
33,599 lb
Penalty in EPA's 2025 settlement
$28,152

Source: EPA consent agreement and final order, Allen Distribution, April 15, 2025

How a filing runs

The same four stages for every site, whether it is one building or forty.

  1. Scope

    Confirm which sites cross a Tier II threshold and which buildings fall under WAIRE, then send a fixed quote in writing.

    A site list with addresses and square footage.

  2. Inventory

    Build the battery and chemical inventory for each site, or the truck trip count and points ledger for each warehouse, with a source for every figure.

    Forklift and battery lists, safety data sheets, fuel records. For WAIRE, gate or yard logs and records of zero-emission equipment and solar.

  3. Approval

    Send you the draft report and the working file behind it. Nothing is filed until you approve it.

    A review by the person who certifies the report for your company.

  4. Filing

    File in the state's system or in WAIRE POP, send copies to the LEPC and fire department where the state requires it, and hand you the filed copy and confirmation.

    Payment of state or AQMD fees, which are billed to you.

The filing year

  1. DecemberWe send the data request for each siteTier II and WAIRE
  2. January 31Annual WAIRE Report dueWAIRE
  3. FebruaryDrafts go out for sign-off, our target the second weekTier II
  4. March 1Tier II due in every state for the previous calendar yearTier II

Dates from 40 CFR 370.45 and Rule 2305 (d)(7)(C). Our own milestones are targets, set per client in the engagement letter. How it works in detail

Who we file for

Warehouses and 3PLs whose reports are driven by batteries, fuel, propane and refrigeration, not process chemistry.

A good fit

  • Warehouse, distribution center and cold storage operators with electric forklifts, generator or fire pump diesel, propane cylinders or ammonia refrigeration.
  • 3PLs running buildings for several clients, where the question is whose chemicals go on whose report.
  • Companies with sites in several states that want one inventory method and each state's own system handled.
  • Operators in South Coast AQMD buildings of 100,000 sq ft or more that owe Annual WAIRE Reports, including missed years after a notice of violation.

Better served elsewhere

  • Chemical manufacturers and plants reporting dozens of process chemicals, or sites that also need TRI Form R, air permits or Risk Management Plans: an engineering consultancy fits better.
  • Companies that want software to run filings themselves across hundreds of sites.
  • Anyone who needs legal advice or a negotiator for a penalty. We are not a law firm.
  • Sites where no chemical reaches a threshold. If scoping shows that, we tell you and charge nothing for that site.

Pricing

A fixed fee per site or per report year, set in writing before work starts.

First and second site

Tier II

$950

per site per year

  • Battery and chemical inventory
  • Threshold review against federal and state rules
  • Filing in the state's system
  • Copies to the LEPC and fire department where the state requires it
  • Filed copy and working file

Extra: state filing fees, paid by you to the state.

Get a quote

Third site onward

Tier II, multi-site

$750

per site per year

  • The same work as a single site
  • One inventory method across every building
  • Each state's own system, fields and copies
  • Five sites: $4,150 a year in total
  • Ten sites: $7,900 a year in total

Extra: state filing fees, paid by you to each state.

Get a quote

South Coast AQMD warehouses

WAIRE

$2,500

per warehouse per report year

  • Annual WAIRE Report, prepared and filed in WAIRE POP
  • Truck trip count and points calculation from your records
  • Evidence file for every action claimed
  • Missed years filed at the same price per year

Extra: AQMD filing fees and any mitigation fees, paid by you to AQMD.

Get a quote

Agency fees are paid by you to the agency, never through us. Full pricing and worked examples.

Every number has a source

Thresholds, deadlines, fees and penalties on this site come from the regulation or the agency's own page, and each guide lists its sources. These are the figures the work rests on.

FigureValueSource
Tier II threshold, sulfuric acid500 lb, all batteries on site combined40 CFR 370.10(a)(1)
Forklift batteries countConsumer product exemption does not applyEPA forklift battery FAQ
Tier II threshold, most other chemicals10,000 lb40 CFR 370.10(a)(2)
Tier II due dateMarch 1, for the prior calendar year40 CFR 370.45
Federal Tier II feeNoneEPA general reporting guidance
EPA's in-house estimate, small non-manufacturing site10.25 hours, $776.11 a yearEPA ICR 1352.19, June 2026
Maximum EPA penalty, section 312$71,545 per violation, each day a separate violation40 CFR 19.4
Acid share EPA usedAbout 30% of battery weightAllen Distribution order, 2025
Annual WAIRE Report dueJanuary 31, for the prior calendar yearRule 2305 (d)(7)(C)
WAIRE points owedWeighted truck trips × 0.0025 × 1.0 from 2026Rule 2305 (d)(1), Table 2
WAIRE mitigation fee$1,000 per point, plus 6.25%Rule 2305 (d)(5), Rule 316 (f)
Annual WAIRE Report filing fee$456.00, plus $556.93 if filed lateRule 316, amended May 1, 2026

How we check facts and log corrections

Guides and free tools

The same rule text and state data we use for client filings, published with sources.

Common questions

Do electric forklifts really count for Tier II?

Yes. EPA says the consumer product exemption does not cover forklift batteries, so their sulfuric acid counts toward the 500 lb threshold, added up across every battery on site, spares included. The battery calculator gives a yes or no from three numbers.

Who signs the report?

Your company does. The owner or operator, or its officially designated representative, certifies each Tier II report under 40 CFR 370.42. We prepare it, you approve it, then it is submitted. In Arizona we prepare the report and your own employee submits it.

Are state and AQMD fees included?

No. State filing fees, AQMD filing fees and WAIRE mitigation fees are paid by you to the agency. Our fee covers the work. The states table shows each state's fee where it is published.

We never filed WAIRE. Is it too late?

No. WAIRE POP takes late reports, and AQMD says a complete and accurate late report is the only way to end ongoing non-compliance for not reporting. Late reports owe an extra AQMD fee and can still bring a penalty. We file missed years at $2,500 each. See late and missed WAIRE reports.

Do you give legal advice?

No. We prepare and file reports and keep the records. If a notice of violation turns into a penalty negotiation, that belongs with your counsel, and we hand them the filed reports and working papers.

A long pallet-racking aisle in a distribution center at night, a reach truck at the far end

Tell us about your sites

Send your site list. We reply by email with which sites need a Tier II report, which buildings fall under WAIRE, and a fixed quote for the work.

Prefer email? Write to

Get a fixed quote

Tell us how many sites you run and where. We reply by email with which sites owe a Tier II report, which buildings fall under WAIRE, and a fixed price.

We use this only to reply to you. Or email .