| Key facts | |
|---|---|
| Stands for | Local emergency planning committee |
| Appointed by | The state emergency response commission (40 CFR 370.3) |
| How many | One for each of more than 3,000 planning districts |
| Duties | Write the emergency response plan, review it at least once a year, and give the public chemical information |
| Receives | Tier II reports, under 40 CFR 370.44 |
LEPC meaning
LEPC stands for local emergency planning committee. The term comes from the Emergency Planning and Community Right-to-Know Act of 1986. 40 CFR 370.3 defines the LEPC as the local emergency planning committee appointed by the state emergency response commission (SERC). EPA counts one emergency planning committee for each of more than 3,000 designated local and tribal emergency planning districts. On tribal land the same role is played by a tribal emergency planning committee, or TEPC.
What LEPCs are charged with
EPA's answer: under EPCRA, local and tribal emergency planning committees must develop an emergency response plan, review the plan at least annually, and provide information about chemicals in the community to citizens. The plan covers the facilities and transportation routes where extremely hazardous substances are found, and it is built with stakeholder participation.
| Required element of the community plan | What it means for a warehouse |
|---|---|
| Facilities and transportation routes of extremely hazardous substances | Sites with battery acid or ammonia at the planning quantity are on the map |
| Emergency response procedures, on and off site | Responders plan around what your Tier II says is in the building |
| A community coordinator and facility emergency coordinators | Facilities subject to section 302 name a coordinator |
| Emergency notification procedures | How a release at your site gets reported |
| How to determine the probable affected area and population | Uses the quantities and locations you report |
| Local emergency equipment and the people responsible for it | Fire department resources |
| Evacuation plans | Neighbors and your own staff |
| Training for emergency responders, with schedules | Some fire departments ask to tour sites |
| Methods and schedules for exercising the plan | Drills that may involve your facility |
Who sits on an LEPC
At a minimum, EPA lists elected state, local and tribal officials; police, fire, civil defense and public health professionals; environment, transportation and hospital officials; facility representatives; and representatives of community groups and the media. Facility representatives are members, so a warehouse can take a seat.
How a warehouse deals with its LEPC
- Tier II, every year. The LEPC is one of the three recipients under 40 CFR 370.44, unless your state forwards it. See who receives the report.
- Section 311 SDSs or list. One time, plus any SDS the LEPC requests, due within 30 days of the request.
- Section 302 notice. If an extremely hazardous substance reaches its threshold planning quantity, such as 1,000 lb of sulfuric acid in batteries, the facility notifies the SERC and LEPC within 60 days and names a facility emergency coordinator (40 CFR 355.20). Changes relevant to planning go to the LEPC within 30 days.
- Section 304 release notice. If a reportable quantity of an extremely hazardous substance or CERCLA hazardous substance is released, the facility notifies the LEPC's community emergency coordinator and the SERC immediately, then sends a written follow-up as soon as practicable (40 CFR 355.40 to 355.43). In the 2024 Sherwood Food Distributors case, late notice of an ammonia release was part of a $150,000 settlement.
- Requests for information. The LEPC can ask for Tier II information at any time, due within 30 days, and for information it needs for the plan, due promptly.
- Public requests. Anyone can ask the LEPC in writing for a facility's Tier II information or SDSs; the LEPC must respond within 45 days (40 CFR 370.60 and 370.61).
- Local fees. Some LEPCs bill separately. Pennsylvania says the LEPC sends its own invoice, and South Carolina tells facilities to check with the county LEPC about fees.
LEPCs also notice missing reports. In the 2025 Allen Distribution case, the local emergency planning committee told EPA that the distribution center had not filed Tier II reports. The settlement carried a $28,152 penalty.
Finding your LEPC
EPA tells facilities to contact their SERC to find the LEPC. EPA also publishes LEPC boundary files, supplied by the SERCs, for mapping. Many state Tier II pages list LEPC contacts, and Connecticut pre-populates the LEPC in its Hazconnect system.
LEPC directories by state
These are the official LEPC lists we found on each state's own site, checked November 24, 2026: 39 of 51 jurisdictions publish one. For the rest, ask the state commission listed on the state page.
Common questions
Under EPCRA, LEPCs are charged with the responsibility to do what?
To develop a community emergency response plan, review it at least annually, and provide information about chemicals in the community to citizens. That is EPA's own summary of the LEPC role.
Who appoints the LEPC?
The state emergency response commission. 40 CFR 370.3 defines the LEPC as the local emergency planning committee appointed by the SERC.
Is the LEPC the same as the fire department?
No. The fire department is a separate recipient of Tier II reports, although fire officials sit on LEPCs.
We build the battery and chemical inventory, check every threshold and file in your state's system. $950 a site per year, $750 a site from the third site. State fees extra.
Get a quote- EPA, Local Emergency Planning Committees
- 40 CFR 370.3, definition of LEPC (eCFR)
- 40 CFR 370.44, recipients (eCFR)
- 40 CFR 370.61, public access to Tier II (eCFR)
- 40 CFR 355.20, emergency planning notification (eCFR)
- EPA, EPCRA hazardous chemical inventory reporting: general reporting guidance
- EPA Region 3, Allen Distribution consent agreement, EPCRA-03-2025-0070
- Pennsylvania L&I, Tier II and PATTS
- South Carolina DES, Tier II
- Connecticut SERC, reporting requirements under EPCRA
- 40 CFR 355.40 to 355.43, emergency release notification (eCFR)
- EPA Region 5, Sherwood Food Distributors consent agreement, EPCRA-05-2024-0024