| Key facts | |
|---|---|
| Due | January 1 to March 1 |
| Where you file | Tier II Manager |
| State fee | No state fee |
| Typical warehouse fee | $0 (battery acid and diesel, filed on time) |
| LEPC and fire department | Online in listed counties, otherwise send copies |
Where and how to file in Michigan
Michigan Department of Environment, Great Lakes, and Energy (EGLE), Michigan SARA Title III Program, with the SERC (Michigan State Police EMHSD) runs Tier II for the state. Tier II Manager (Michigan's official online system; one submission covers 302, 311 and 312 data). The filing system is at egle.state.mi.us.
EPA's state page, last updated May 28, 2026, gives these instructions for Michigan:
Reports must be submitted online using the Tier II Manager™ software. Access this program by going to the SARA website and selecting "SARA Title III Hazardous Chemical Inventory." Access the latest version of the "Michigan Facilities' Guide to SARA Title III, Emergency Planning, and Release Reporting" by going to the SARA website and selecting "SARA Title III." Additional information can be found in CHAPTER 3: SARA TITLE III - Sections 311 and 312 EMERGENCY AND HAZARDOUS CHEMICAL INVENTORY REPORTING document (pdf)(2.1 MB).
Fees in Michigan
No state fee. The source reads: "There is no fee associated with reports submitted in Tier II Manager™." Fee source.
Late fee: not published on the pages we read.
Deadline
Between January 1 and March 1 for the previous calendar year. Under federal rules the report is due on or before March 1 each year for the previous calendar year, so the report covering 2026 is due by March 1, 2027.
Copies to the LEPC and fire department
LEPCs and fire departments in listed counties receive reports online through Tier II Manager; in all other counties the report must be mailed or emailed (paper copy) directly to the LEPC and fire department.
State-specific requirements
Fields and attachments the state asks for
- Select the primary fire department that will respond and receive the report; enter 6-digit 2012 NAICS code(s). Source: michigan.gov
- Site maps and SDSs can be attached; attachments such as site maps can be marked confidential. Source: michigan.gov
State rules beyond federal Tier II
- Update report due within 3 months after a chemical threshold is first met. Source: michigan.gov
- SERC, LEPC or fire department may request Tier II information regardless of amount; respond within 30 days. Source: michigan.gov
Other things to know
- Michigan lists the counties whose LEPCs and fire departments accept Tier II reports online (e.g., Kent, Macomb, Oakland, Wayne). Source: michigan.gov
- More than 6,000 Michigan facilities file hazardous chemical inventories. Source: michigan.gov
- EGLE offers tutorials and webinars on Tier II reporting; help via egle-sara@michigan.gov or Environmental Assistance Center 800-662-9278. Source: michigan.gov
Also checked on November 24, 2026
- Michigan's Fire Prevention Code (Act 207 of 1941, section 29.5p) separately requires every employer to give the fire chief hazardous substance information and SDSs on written request. Source: michigan.gov
- Consultants register one account of their own; the company emails the Administrator with subject 'Consultant Needs Access' to move facilities to the consultant. Source: michigan.gov
How to file in Michigan, step by step
The steps a first-time filer follows, from the state's own instructions as read on November 24, 2026:
- Email the Administrator (egle-sara@michigan.gov) with the names and addresses of your facilities to check whether they are already in the system before registering. Source: michigan.gov
- Register in Tier II Manager as a 'Reporting Facility/Business User' and wait for the approval email. Source: michigan.gov
- File the Annual (Tier II) report online between January 1 and March 1; one online report covers the Section 302, 311 and 312 data. Source: michigan.gov
- If the facility's county is not on the participating list, mail or email the report directly to the county LEPC and the local fire department. Source: michigan.gov
What a typical warehouse pays in Michigan
Illustrative: one general warehouse (NAICS 493110), 40 employees, filing on time for calendar year 2026, reporting two chemicals: sulfuric acid in lead acid forklift batteries (an extremely hazardous substance, 7,260 lb on site) and diesel in a generator tank (11,900 lb). Applying the state's published fee rule, that warehouse pays $0 to the state for the year.
How it adds up: No state fee = $0. Route assumed: michigan Tier II Manager (free, hosted by the Michigan SARA Title III Program); E-Plan not used, so no $25 E-Plan charge. None beyond the profile.
Local fees, if any, are not included. Compare every state on what Tier II costs per facility. Fee rule: michigan.gov
Does Michigan use the federal thresholds?
Michigan applies the federal 40 CFR Part 370 thresholds; any amount must be reported if the SERC, LEPC or fire department asks for it. Source: michigan.gov
Federal thresholds under 40 CFR 370.10: 500 lb or the threshold planning quantity, whichever is lower, for extremely hazardous substances such as the sulfuric acid in forklift batteries, and 10,000 lb for other hazardous chemicals such as diesel and propane.
Who to contact in Michigan
Michigan EGLE, Michigan SARA Title III Program (accepts reports on behalf of the SERC): phone 517-284-7272 (517-284-SARA), email egle-sara@michigan.gov. Source: michigan.gov
To find your local emergency planning committee, use the state's official LEPC list.
What warehouses in Michigan usually report
Most warehouse Tier II reports start with the sulfuric acid in lead acid forklift batteries. Sulfuric acid is an extremely hazardous substance, so the acid in every battery on site, spares included, is added up and compared to 500 lb. EPA says the consumer product exemption does not apply to forklift batteries. After that come diesel in generator and fire pump tanks, propane cylinders, and anhydrous ammonia in cold storage. The battery calculator and the threshold checker run the numbers.
What we could not confirm
We could not confirm a late fee on an official Michigan page. Where a field says not published, we say so rather than guess. We recheck these pages each January before filing season.
Other states: Massachusetts · Minnesota · all states
Common questions
Does Michigan charge a Tier II fee?
There is no Michigan state fee. Source: michigan.gov.
Where do I file Tier II in Michigan?
Tier II Manager (Michigan's official online system; one submission covers 302, 311 and 312 data).
Do I send copies to the LEPC and fire department in Michigan?
LEPCs and fire departments in listed counties receive reports online through Tier II Manager; in all other counties the report must be mailed or emailed (paper copy) directly to the LEPC and fire department.
When is the Michigan Tier II report due?
Between January 1 and March 1 for the previous calendar year. Under federal rules the report is due on or before March 1 each year for the previous calendar year, so the report covering 2026 is due by March 1, 2027.
How much does a typical warehouse pay for Tier II in Michigan?
$0 in state fees for one warehouse reporting battery acid and generator diesel, filed on time: No state fee = $0. Local fees are not included.
Does Michigan have lower Tier II thresholds than the federal rule?
Michigan applies the federal 40 CFR Part 370 thresholds; any amount must be reported if the SERC, LEPC or fire department asks for it.
Who do I contact about Tier II in Michigan?
Michigan EGLE, Michigan SARA Title III Program (accepts reports on behalf of the SERC): phone 517-284-7272 (517-284-SARA), email egle-sara@michigan.gov.
We build the battery and chemical inventory, check every threshold and file in your state's system. $950 a site per year, $750 a site from the third site. State fees extra.
Get a quote- Michigan Department of Environment, Great Lakes, and Energy (EGLE), Michigan SARA Title III Program, with the SERC (Michigan State Police EMHSD), Tier II page
- Michigan fee source
- EPA, State Tier II Reporting Requirements and Procedures (updated May 28, 2026)
- 40 CFR 370.45, when inventory information is due (eCFR)
- 40 CFR 370.44, who receives the report (eCFR)
- EPA, Forklift batteries
- Michigan LEPC list